missing translation for 'onlineSavingsMsg'
Learn More
Learn More
IBA Lifesciences Strep-tag™ Protein Purification Buffer Set, IBA Lifesciences GmbH
Shop All IBA Lifesciences ProductsDescription
Strep-Tactin™ Buffer Set contains all buffers necessary for purification of Strep-tag™II or Twin-Strep-tag™ fusion proteins with Strep-Tactin™ as well as for subsequent regeneration of the resin. Strep-Tactin™XT Buffer Set comprises the following buffers:
• 10x Buffer W, 100 ml
• 10x Buffer BXT, 25 ml
• 10x Buffer XT-R, 250 ml 10x Buffer W is a 10x concentrated wash buffer for Strep-Tactin™ and Strep-Tactin™XT resins. It removes unbound molecules from the affinity chromatography matrix during Strep-tag™II and Twin-Strep-tag™ fusion protein purification. 10x Buffer E is a 10x concentrated Strep-Tactin™ elution buffer. The contained desthiobiotin is a modified form of biotin that displaces Strep-tag™II and Twin-Strep-tag™ fusion proteins from the modified biotin-binding pocket of Strep-Tactin™ in a competitive manner, resulting in a mild elution. Please note that 10x Buffer E is not applicable for elution from Strep-Tactin™XT resins. 10x Buffer R is a 10x concentrated Strep-Tactin™ regeneration buffer containing HABA. HABA (2-[4-hydroxy-benzeneazo]benzoic acid) displaces desthiobiotin from the modified biotin-binding pocket of Strep-Tactin™ after the elution of Strep-tag™II or Twin-Strep-tag™ fusion proteins. The yellow buffer turns red upon binding of HABA to Strep-Tactin™, clearly indicating the regeneration process and activity status of the column.
Please note that the Strep-Tactin™ Buffer Set is not applicable for Strep-Tactin™XT.
• 10x Buffer W, 100 ml
• 10x Buffer BXT, 25 ml
• 10x Buffer XT-R, 250 ml 10x Buffer W is a 10x concentrated wash buffer for Strep-Tactin™ and Strep-Tactin™XT resins. It removes unbound molecules from the affinity chromatography matrix during Strep-tag™II and Twin-Strep-tag™ fusion protein purification. 10x Buffer E is a 10x concentrated Strep-Tactin™ elution buffer. The contained desthiobiotin is a modified form of biotin that displaces Strep-tag™II and Twin-Strep-tag™ fusion proteins from the modified biotin-binding pocket of Strep-Tactin™ in a competitive manner, resulting in a mild elution. Please note that 10x Buffer E is not applicable for elution from Strep-Tactin™XT resins. 10x Buffer R is a 10x concentrated Strep-Tactin™ regeneration buffer containing HABA. HABA (2-[4-hydroxy-benzeneazo]benzoic acid) displaces desthiobiotin from the modified biotin-binding pocket of Strep-Tactin™ after the elution of Strep-tag™II or Twin-Strep-tag™ fusion proteins. The yellow buffer turns red upon binding of HABA to Strep-Tactin™, clearly indicating the regeneration process and activity status of the column.
Please note that the Strep-Tactin™ Buffer Set is not applicable for Strep-Tactin™XT.
Specifications
Specifications
| Chemical Name or Material | Buffer W, Buffer E, Buffer R |
| For Use With (Application) | Purification of recombinant Strep-Tag fusion proteins on immobilized Strep-Tactin |
| Quantity | 1 Kit |
| Solution Type | Protein Purification Buffer |
Safety and Handling
Product Identifier
- Strep-Tactin purification buffer set
- Warning
- Serious eye damage/eye irritation Category 2
- Skin corrosion/irritation Category 2
- Specific target organ toxicity Category 3
- Specific target organ toxicity after repeated exposure Category 2
- Acute toxicity Category 4
- H315-Causes skin irritation.
- H319-Causes serious eye irritation.
- H335-May cause respiratory irritation.
- H372-Causes damage to organs.
- P264-Wash hands thoroughly after handling.
- P280-Wear protective gloves/protective clothing/eye protection/face protection.
- P302+P352-IF ON SKIN: Wash with plenty of water/soap and water.
- P305+P351+P338-IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P332+P313-If skin irritation occurs: Get medical advice/attention.
- P337+P313-If eye irritation persists: Get medical advice/attention.
For Research Use Only.
Product Title
By clicking Submit, you acknowledge that you may be contacted by Fisher Scientific in regards to the feedback you have provided in this form. We will not share your information for any other purposes. All contact information provided shall also be maintained in accordance with our Privacy Policy.
Spot an opportunity for improvement?