PCR Supplies
Filtered Search Results
Thermo Scientific™ GeneJET PCR Purification Kit
Thermo Scientific GeneJET PCR Purification Kit utilizes a proprietary silica-based membrane technology in the form of a convenient spin column, eliminating the need for tedious resin manipulations or toxic phenol-chloroform extractions.
| Content And Storage | For better long-term performance, it is recommended to store the purification columns at 2°C to 8°C. |
|---|---|
| Format | Spin Column |
| Run Time | 5 min. |
| High-throughput Compatibility | Not High-throughput Compatible (Manual) |
Invitrogen™ dNTP Set (100 mM)
Invitrogen 100 mM dNTP Mix is a mixture of four nucleotides (dATP, dCTP, dGTP, dTTP) in purified water. Each nucleotide is at a concentration of 100 mM.
| Shipping Condition | Approved for shipment on Wet or Dry Ice |
|---|---|
| Form | Liquid |
| Label or Dye | Unlabeled |
| Concentration | 100 mM |
| For Use With (Application) | Standard PCR,RT-PCR,Real Time PCR (qPCR) |
Thermo Scientific™ RevertAid Reverse Transcriptase (200 U/μL)
Thermo Scientific RevertAid Reverse Transcriptase (RT) is a recombinant M-MuLV RT. It differs from the M-MuLV RT by its structure and catalytic properties.
| Shipping Condition | Dry Ice |
|---|---|
| Content And Storage | • RevertAid Reverse Transcriptase (200 U/μL) |
| Reverse Transcriptase | RevertAid |
| Final Product Type | First-Strand cDNA |
| Concentration | 200 U/μL |
| Format | Stand-alone Enzyme |
| Size (Final Product) | Up to 13 kb |
| Reaction Format | Separate components |
| Reaction Speed | 60 min. |
| Reagent Type | Reverse Transcription |
| Ribonuclease H Activity | Yes |
| Optimal Reaction Temperature | 42°C |
| Technique | Reverse Transcription |
| Starting Material | RNA |
Thermo Scientific™ Phire Plant Direct PCR Master Mix
Thermo Scientific Phire Plant Direct PCR Master Mix is designed to amplify DNA directly from plant samples.
| Shipping Condition | Wet or Dry Ice |
|---|---|
| Polymerase | Phire Hot Start II DNA Polymerase |
| GC-Rich PCR Performance | Medium |
| Reaction Format | SuperMix or Master Mix |
| Product Type | Direct PCR Master Mix |
| Sample Type | Plant |
| Reaction Speed | Fast |
| Hot Start | Built-In Hot Start |
| Overhang | Blunt |
| Concentration | 2X |
| Starting Material | DNA |
| For Use With (Application) | Genotyping,Hot-start PCR |
| PCR Method | Direct PCR |
Applied Biosystems™ PowerUp™ SYBR™ Green Master Mix for qPCR
Pre-formulated, optimized, universal 2X master mix for real-time PCR workflows.
| Shipping Condition | Wet Ice |
|---|---|
| Concentration | 2X |
| For Use With (Application) | Gene Expression |
| PCR Method | qPCR |
| Multiplex Capability | Single-plex |
| Detection Method | SYBR |
| Includes | dUTP, UNG/UDG |
| Thermostability | 72 hr., Assembled Reaction |
| Polymerase | Dual-Lock Taq DNA Polymerase |
| Format | Tube |
| Product Type | Real Time PCR SYBR Master Mix |
| Passive Reference Dye | ROX (Pre-mixed) |
| For Use With (Equipment) | 7500 Fast System, 7500 System, 7900HT System, QuantStudio 12k Flex, QuantStudio 3, QuantStudio 5, QuantStudio 6 Flex, QuantStudio 6 Pro, QuantStudio 7 Pro, QuantStudio 7 Flex, StepOne, StepOnePlus, ViiA 7 System, Roche LightCycler PRO System, Bio-Rad CFX Opus 96 Real-Time PCR System |
| Sample Type | DNA |
| Reaction Speed | Fast or Standard |
| Inhibitor Tolerance (Simple) | Medium |
| Target Specificity | cDNA or gDNA only |
| Product Line | PowerUP, SYBR |
Applied Biosystems™ resDNASEQ™ Quantitative E. coli DNA Kits
This quantitative PCR (qPCR)-based kit, part of the resDNASEQ™ E. coli Residual DNA Quantitation System, enables highly sensitive quantitation of host cell DNA from E. coli expression systems, typically in less than 4 hours.
| No. of Reactions | 100 Reactions |
|---|---|
| Format | Kit |
| Label or Dye | FAM |
| Quantity | 100 reactions |
| Host Cell | E.coli |
| PCR Method | qPCR |
| Product Line | resDNASEQ |
| Detection Method | Primer-probe |
Thermo Scientific™ Phusion High-Fidelity PCR Master Mix with HF or GC Buffer
Thermo Scientific Phusion High-Fidelity DNA polymerases set a gold standard for high performance PCR.
| Shipping Condition | Dry Ice |
|---|---|
| Polymerase | Phusion High-Fidelity DNA Polymerase |
| Fidelity (vs. Taq) | 52X |
| Size (Final Product) | 20 kb or less |
| Reaction Format | SuperMix or Master Mix |
| Product Type | High-Fidelity PCR Master Mix |
| Reaction Speed | Fast |
| Hot Start | No |
| Overhang | Blunt |
| Concentration | 2X |
| For Use With (Application) | Standard PCR,High-fidelity PCR |
Invitrogen™ SuperScript™ IV First-Strand Synthesis System
The SuperScript IV First-Strand Synthesis System for RT-PCR, available with or without ezDNase, is optimized for synthesis of first-strand cDNA from purified poly(A)+ or total RNA.
| GC-Rich PCR Performance | High |
|---|---|
| Format | Kit |
| Reverse Transcriptase | SuperScript IV |
| Size (Final Product) | Up to 12.3 kb |
| Reaction Format | Separate components |
| Final Product Type | First-Strand cDNA |
| Reaction Speed | 10 min. |
| Reagent Type | Reverse Transcription |
| Quantity | Each |
| Optimal Reaction Temperature | 50°C |
| Technique | Reverse Transcription |
| Starting Material | RNA |
Invitrogen™ dNTP Mix (10 mM ea)
Invitrogen 10 mM dNTP Mix includes four nucleotides (dATP, dCTP, dGTP, dTTP) in 0.6 mM Tris-HCl. Each nucleotide is at a concentration of 10 mM and this mix is suitable for use in a wide variety of molecular processes.
| Shipping Condition | Approved for shipment on Wet or Dry Ice |
|---|---|
| Form | Liquid |
| Label or Dye | Unlabeled |
| Concentration | 10 mM |
| For Use With (Application) | Standard PCR,RT-PCR,Real Time PCR (qPCR) |
Invitrogen™ Taq DNA Polymerase, recombinant
Taq DNA Polymerase is a thermostable enzyme that synthesizes DNA from single-stranded templates in the presence of dNTPs and a primer.
| Shipping Condition | Dry Ice |
|---|---|
| GC-Rich PCR Performance | Low |
| Fidelity (vs. Taq) | 1X |
| Overhang | 3'-A |
| Concentration | 5 U/μL |
| For Use With (Application) | Standard PCR |
| PCR Method | qPCR,Standard PCR |
| Exonuclease Activity | 5' - 3' |
| Polymerase | Taq DNA Polymerase |
| Format | Stand-alone enzyme |
| Size (Final Product) | 5 kb or less |
| Reaction Format | Separate Components |
| Product Type | DNA Polymerase |
| Reaction Speed | Standard |
| Hot Start | No |
| Starting Material | DNA |
Applied Biosystems™ Power SYBR™ Green RNA-to-CT™ 1-Step Kit
The novel formulation reduces false positive results caused by primer dimers, significantly improves data accuracy, and provides reliable detection of low abundance targets.
| Shipping Condition | Wet Ice |
|---|---|
| Purity or Quality Grade | UP (Ultra Pure) |
| Reverse Transcriptase | ArrayScript™ UP |
| For Use With (Application) | Gene Expression |
| PCR Method | 1-step RT-qPCR |
| Detection Method | SYBR |
| Polymerase | AmpliTaq Gold DNA Polymerase |
| Passive Reference Dye | ROX (Pre-mixed) |
| For Use With (Equipment) | 7500 Fast System, 7500 System, 7900HT System, QuantStudio™ 12k Flex, QuantStudio™ 3, QuantStudio™ 5, QuantStudio™ 6 Flex, QuantStudio™ 7, StepOne™, StepOnePlus™, ViiA™ 7 System |
| Sample Type | RNA |
| Reaction Speed | Standard |
| Label or Dye | SYBR Green |
| Run Time | Standard |
| Product Line | RNA-to-CT, SYBR |
Invitrogen™ PureLink™ PCR Purification Kit
The PureLink PCR Purification Kit provides a more convenient, rapid, and high-yielding purification process compared to other companies' kits.
| Shipping Condition | Room Temperature |
|---|---|
| Content And Storage | For better long-term performance, it is recommended to store the purification columns at 2°C to 8°C. |
| Format | Kit |
| Sample Type | PCR Products |
| Isolation Technology | Silica Spin Column |
| Run Time | 10 min. |
Thermo Scientific™ RevertAid H Minus Reverse Transcriptase (200 U/μL)
Thermo Scientific RevertAid H Minus Reverse Transcriptase is a recombinant M-MuLV RT. The enzyme possesses an RNA-dependent and DNA-dependent polymerase activity, but lacks RNase H activity due to a point mutation in the RNase H domain.
| Shipping Condition | Dry Ice |
|---|---|
| Content And Storage | • RevertAid H Minus Reverse Transcriptase (200 U/μL) |
| Reverse Transcriptase | RevertAid H Minus |
| Final Product Type | First-Strand cDNA |
| Concentration | 200 U/μL |
| Format | Stand-alone Enzyme |
| Size (Final Product) | Up to 13 kb |
| Reaction Format | Separate components |
| Reaction Speed | 60 min. |
| Reagent Type | Reverse Transcription |
| Ribonuclease H Activity | Reduced |
| Optimal Reaction Temperature | 42°C to 45°C |
| Technique | Reverse Transcription |
| Starting Material | RNA |
Invitrogen™ AccuPrime™ Taq DNA Polymerase, High Fidelity
Invitrogen AccuPrime Taq DNA Polymerase, High Fidelity, provides qualified reagents for the high-fidelity PCR amplification of nucleic acid templates.
| Shipping Condition | Dry Ice |
|---|---|
| Polymerase | AccuPrime Taq DNA Polymerase High Fidelity |
| GC-Rich PCR Performance | Low |
| Fidelity (vs. Taq) | 9X |
| Size (Final Product) | 20 kb or less |
| Reaction Format | Separate Components |
| Product Type | DNA Polymerase |
| Reaction Speed | Standard |
| Hot Start | Built-In Hot Start |
| For Use With (Application) | Hot-start PCR,High-fidelity PCR |
| Detection Method | Primer-probe |
Applied Biosystems™ TaqMan™ MicroRNA Reverse Transcription Kit
Provides the necessary components for 200 reactions of optimal performance in TaqMan™ MicroRNA Assays.
| Shipping Condition | Dry Ice |
|---|---|
| GC-Rich PCR Performance | High |
| Fidelity (vs. Taq) | 10 X |
| Reverse Transcriptase | MultiScribe™ |
| Final Product Type | cDNA |
| Concentration | 10X |
| For Use With (Application) | miRNA analysis |
| PCR Method | 2-step RT-qPCR |
| Detection Method | Primer-probe |
| Size (Final Product) | 200 bp or less |
| Reaction Format | Separate Components |
| Product Type | MicroRNA Reverse Transcription Kit |
| Sample Type | RNA |
| Reaction Speed | Fast |
| Optimal Reaction Temperature | 42°C |
| Product Line | TaqMan |