Measure sodium ions in aqueous solution quickly, accurately and economically.

Measure sodium in aqueous solutions quickly, accurately and economically with Thermo Scientific™ Orion™ Sodium Electrodes. A unique redox internal system with a Thermo Scientific™ Orion™ ROSS™ electrode provides faster response, and greater stability and accuracy than conventional sodium electrodes.

The sodium electrode is commonly used to measure samples such as food, beverages and animal feed.

Features:

  • 8611BNWP is a combination electrode with a Sure-Flow™ junction that allows easy cleaning. When conventional electrode junctions clog, the Sure-Flow junction can be opened and flushed clean simply by pressing the cap. 8411BN is a half cell sensor that requires ROSS reference electrode, Cat. No. 800300 or the ROSS Ultra reference electrode, Cat. No. 800500U to function.

Solutions required:

  • Standards
    • 941706 0.1 M NaCl sodium standard solution, 475 mL bottle
    • 841108 1000 ppm sodium standard solution, 475 mL bottle
    • 941107 100 ppm sodium standard solution, 475 mL bottle
    • 941105 10 ppm sodium standard solution, 475 mL bottle
  • Known standards addition
    • 841109 Sodium known addition standard, 1000 ppm with ISA, 475 mL bottle
    • 650700 Sodium known addition standard, 1 M with ISA, 475 mL bottle
  • ISA
    • 841111 Sodium ISA, 475 mL bottle
  • Electrode fill solution
    • 900010 ROSS sodium and reference electrode filling solution, 5 x 50 mL bottles.
    • For regular sodium measurements (> 10-5 M or 0.2 ppm)
    • 900012 ROSS sodium and reference electrode filling solution, 5 x 50 mL bottles.
    • For low-level sodium measurements (< 10-5 M or 0.2 ppm)
    • 841101 Sodium electrode storage solution, 475 mL bottle
  • Recondition solution
    • 841113 Sodium electrode reconditioning solution, 475 mL bottle

Items included with:

  • 841113 Sodium electrode reconditioning solution, 475 mL bottle
  • 841111 Sodium ISA, 475 mL bottle
  • 841109 Sodium known addition standard, 1000 ppm with ISA, 475 mL bottle
  • 841108 1000 ppm sodium standard solution, 475 mL bottle
  • 900010 ROSS sodium and reference electrode. 60mL 1 bottle
  • 841101 Sodium electrode storage solution, 475 mL bottle

Warranty period:

  • 12 months from date of purchase by Buyer or 18 months from date of shipment from Seller, whichever is earlier.
TRUSTED_SUSTAINABILITY

Especificaciones

Connector Types BNC (Waterproof)
Description ROSS sodium combination electrode
Diameter (English) Body 0.47 in
Diameter (Metric) Body 12 mm
Filling Solution Type 900010 for regular Na+ (> 10-5 M or 0.2 ppm), 900012 for low level Na+ (< 10-5 M or 0.2 ppm)
Junction Sure-Flow Junction
Length (English) 4.72 in
Length (English) Cable 39.3 in.
Length (Metric) 120 mm
Length (Metric) Cable 1 M
Material Glass
Operating Range (Metric) Saturated to 10-6 M, saturated to 0.02ppm
Temperature (English) Operating 32 to 176°F
For Use With (Equipment) ISE Meter
Temperature (Metric) Operating 0°C to 100°C
Measurement Range
  • 1 x 10-6 M to saturated
  • 0.02 ppm to saturated
Parameter Sodium Combination Ion Selective Electrode
Refillable Yes
Mostrar más Mostrar menos
compliance-icons compliance-icons compliance-icons
Nombre del producto
  • SODIUM SPECIFIC ELECTRODE
Palabra de advertencia
  • Danger
Clasificación
  • Acute toxicity Category 4
  • LONG-TERM AQUATIC HAZARD Chronic 2
  • LONG-TERM AQUATIC HAZARD Chronic 3
  • Serious eye damage/eye irritation Category 1
  • Serious eye damage/eye irritation Category 2
  • Skin corrosion/irritation Category 1 B
  • Skin corrosion/irritation Category 2
  • Specific target organ toxicity Category 3
Indicaciones de peligro
  • H302-Harmful if swallowed.
  • H314-Causes severe skin burns and eye damage.
  • H315-Causes skin irritation.
  • H318-Causes serious eye damage.
  • H319-Causes serious eye irritation.
  • H335-May cause respiratory irritation.
  • H411-Toxic to aquatic life with long lasting effects.
  • H412-Harmful to aquatic life with long lasting effects.
Consejos de prudencia
  • P202-Do not handle until all safety precautions have been read and understood.
  • P260-Do not breathe dust/fume/gas/mist/vapours/spray.
  • P273-Avoid release to the environment.
  • P280-Wear protective gloves/protective clothing/eye protection/face protection.
  • P303+P361+P353-IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water/ shower.
  • P305+P351+P338-IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
  • P310-Immediately call a POISON CENTER/doctor/.
  • P321-Specific treatment (see on this label).
Otros peligros
  • MIXTURE LIST-Contains : ammonium chloride, ammonium hydroxide, triton X-100
Corrección del contenido de un producto

Proporcione sus comentarios sobre el contenido del producto rellenando el siguiente formulario.

Título del producto

Al hacer clic en Enviar, acepta que Fisher Scientific se ponga en contacto con usted en relación con los comentarios que ha proporcionado en este formulario. No compartiremos su información para ningún otro fin. Toda la información de contacto proporcionada se mantendrá de acuerdo con nuestra Política de Privacidad. Política de privacidad.

Gracias por ayudarnos a mejorar nuestra web. Su comentario ha sido enviado