METTLER TOLEDO™ Ion Selective Electrodes (ISE)

Product Code. 11977811 Shop All Mettler Toledo Products
Click to view available options
Connector Types:
BNC
S7 BNC Cable
Model:
perfectION Ag+/S2- Combination Electrode
perfectION CI- Combination Electrode
perfectION CN- Combination Electrode
perfectION CU2+ Combination Electrode
perfectION Ca+2 Combination Electrode
perfectION DX223-Na+ Half-Cell Electrode
perfectION DX235-Cl- Half-Cell Electrode
perfectION FI- Combination Electrode
perfectION I- Combination Electrode
perfectION K+ Combination Electrode
perfectION NO3- Combination Electrode
perfectION Na+ Combination Electrode
perfectION Pb2+ Combination Electrode
Measurement Range:
0.002 to 23000 mg/L
0.005 to 127000 mg/L
0.02 mg/ - saturated solution
0.02 to 40100 mg/L
0.04 to 39000 mg/L
0.1 to 14000 mg/L
0.2 to 20700 mg/L
0.2 to 260 mg/L
1.0 to 1 x 10-7 mol/L
1.0 to 1.0-5 mol/L
1.8 to 35500 mg/L
6.4 x 10-6354 mg/L
Ag+: 0.01 to 108000 mg/L; S2-: 0.003 to 32000 mg/L
Unit Size:
Each
This item is not returnable. View return policy

Product Code. 11977811

Brand: METTLER TOLEDO™ 51344703

Only null left
Add to basket
Add to basket
This item is not returnable. View return policy

A selection of ISE probes for detecting concentration of various free ions.

  • Prior to first use, rinse the electrode with distilled water and soak it in the appropriate standard for 24-48 hours and then fill with reference electrolyte (refer to table above)
  • ISA (Ionic strength adjuster) solution required to be added to all calibration standards and samples prior to measurement for accurate results
  • Refer to electrode user manual for appropriate ratio of ISA solution to sample volume
  • Add filling solution each day before using the electrode (at least 2.5 cm above sample level in beaker)
  • Be sure to screw cap tightly immediately after use
  • The filling solution inside the electrode should not be allowed to evaporate, as crystallization will result
  • For storage between measurements and up to three days, store in the appropriate standard
  • For long-term storage, refer to specific ISE electrode user manual
  • Sensing membrane will wear over time; each membrane can last about six months with normal use, but actual lifespan will depend on the type of samples that are being measured
  • Competing ion interferences are common. Refer to ISE electrode user manual for potential interferences
  • Compatible with METTLER TOLEDO SevenExcellence Benchtop, Seven2Go, and SevenGo Portable
  • Compatible with InMotion Autosampler to automate measurement and cleaning of up to 303 samples
TRUSTED_SUSTAINABILITY

Specifikationer

Applications For determination of Calcium ions
Connector Types BNC
Description Required Solutions: Reference Electrolyte Ion Electrolyte A - 51344750 Ionic Strength Adjuster - 51344761
Filling Solution Type Ion Electrolyte A
Length (English) 4.75 in.
Length (English) Cable 3.9 ft.
Length (Metric) 120 mm
Length (Metric) Cable 1.2 m
Material Epoxy
Temperature (English) Operating 32° to 104°F
pH Range 2.5 to 11
Interferences Ca2+, F-, S2-
Membrane Polymer matrix
Model perfectION Ca+2 Combination Electrode
Temperature (Metric) Operating 0°C to 40°C
Type Ion Selective Electrode
Measurement Range 0.02 to 40100 mg/L
Parameter Calcium
Visa mer Visa mindre
Korrigering av produktinnehåll

Din input är viktig för oss. Fyll i det här formuläret för att ge feedback relaterad till innehållet på denna produkt.

Produkttitel

Genom att klicka på Skicka bekräftar du att du kan bli kontaktad av Fisher Scientific angående feedbacken du har lämnat i detta formulär. Vi kommer inte att dela din information för andra ändamål. All kontaktinformation som tillhandahålls ska också underhållas i enlighet med vår Sekretesspolicy.

Tack! Din feedback har skickats. Fisher Scientific arbetar alltid för att förbättra vårt innehåll åt dig. Vi uppskattar din feedback.