Invitrogen™ CytoVista™ 3D Cell Culture Clearing Reagent

Product Code. 16379573
Click to view available options
Quantity:
10 mL
30 mL
100 mL
Unit Size:
100mL
10mL
30mL
This item is not returnable. View return policy

For Research Use Only. All usage must comply with product instructions.

Product Code. 16379573

Brand: Invitrogen™ V11326

Please to purchase this item. Need a web account? Register with us today!

This item is not returnable. View return policy

For Research Use Only. All usage must comply with product instructions.

CytoVista 3D Cell Culture Clearing Reagent clears fluorescently labeled 3D cultured cells such as organoids and spheroids.

This clearing process enables sharp and bright 3D fluorescent imaging for depths up to 1000 μm. The reagent can also be used as an imaging solution with stable storage of 3D cell cultures for weeks with minimal change in tissue morphology or brightness, or specificity of the fluorophores.

Features of the CytoVista family of tissue and 3D cell culture clearing reagents include:
• Rapid clearing of fluorescently labeled tissue for 3D imaging
• Minimal shrinkage, expansion, or other morphological changes to tissue
• Simple workflow does not require any special instruments or equipment and is easily adapted to IHC
• Compatible with most fluorophores, including dyes and fluorescent proteins

The CytoVista tissue and 3D cell culture clearing workflow clears tissue or 3D cultured cells with minimal changes to morphology or the sensitivity of detection with almost any fluorophore. With an easy-to-use protocol, whole mouse brain (8-mm section) can be cleared in 24 hours, or a 1-mm section in 2 hours, without the use of any special instruments or equipment.

The CytoVista clearing workflow is compatible with most fluorophores, including fluorescent proteins that are detected with common fluorescent imaging instruments, such as wide-field microscopes, high content analyzers, confocal microscopes, and lightsheet microscopes. For first time users, we recommend the CytoVista Tissue Clearing/Staining Kit (Cat No V11324) or CytoVista 3D Cell Culture Clearing/Staining Kit (Cat No. V11325). These kits contain all necessary reagents for both clearing and IHC staining.

CytoVista clearing technology sufficiently clears tissue for 3D fluorescent imaging, but unlike other clearing techniques does not significantly changes the tissue morphology. Minimal morphological changes, such as shrinkage and contraction, have been observed. For precious samples, the clearing can be reversed, and the tissue can be processed for histology studies, like H&E staining.

For tissues that are easier to clear, like brain, lung, intestine, skin, and tissues of less than 250-μm thickness, treatment with CytoVista Tissue Clearing Reagent is sufficient for 3D imaging. However, tissues of more than 250-μm thickness or that are hard to clear like kidney, liver, heart, and placenta will require an initial treatment with CytoVista Tissue Clearing Reagent followed by treatment with CytoVista Tissue Clearing Enhancer.

CytoVista 3D Cell Culture Clearing Reagent is recommended for spheroids or organoids up to 1 mm in thickness.

For hard tissues like bone, cartilage, and connective tissue, CytoVista Tissue Clearing Reagent is not recommended.

TRUSTED_SUSTAINABILITY

Specifications

Type 3D Cell Culture Clearing Reagent
Product Line CytoVista
Content And Storage Store at 15°C to 25°C. Do not freeze.
  • When stored as directed, product is stable for (at least 6 months after receipt.
  • )
    Quantity 10 mL
    Shipping Condition Approved for shipment at Room Temperature or on Wet Ice
    compliance-icons compliance-icons compliance-icons compliance-icons compliance-icons
    Product Identifier
    • CytoVista 3D Cell Culture Clearing Reagent
    Signal Word
    • Danger
    Hazard Category
    • Acute toxicity Category 4
    • Serious eye damage/eye irritation Category 1
    • Skin corrosion/irritation Category 2
    • Specific target organ toxicity Category 3
    Hazard Statement
    • H302-Harmful if swallowed.
    • H315-Causes skin irritation.
    • H318-Causes serious eye damage.
    • H332-Harmful if inhaled.
    • H336-May cause drowsiness or dizziness.
    Precautionary Statement
    • P261-Avoid breathing dust/fume/gas/mist/vapours/spray.
    • P264-Wash hands thoroughly after handling.
    • P270-Do not eat, drink or smoke when using this product.
    • P273-Avoid release to the environment.
    • P280-Wear protective gloves/protective clothing/eye protection/face protection.
    • P301+P310-IF SWALLOWED: Immediately call a POISON CENTER/doctor /
    • P302+P352-IF ON SKIN: Wash with plenty of water/soap.
    • P304+P340-IF INHALED: Remove person to fresh air and keep comfortable for breathing.
    • P305+P351+P338-IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
    • P330-Rinse mouth.
    • P403+P233-Store in a well-ventilated place. Keep container tightly closed.
    Supplemental information
    • MIXTURE LIST-Contains : Polyethylene glycol,Benzyl alcohol, methanol

    For Research Use Only. Not for use in diagnostic procedures.

    Product Content Correction

    Your input is important to us. Please complete this form to provide feedback related to the content on this product.

    Product Title

    By clicking Submit, you acknowledge that you may be contacted by Fisher Scientific in regards to the feedback you have provided in this form. We will not share your information for any other purposes. All contact information provided shall also be maintained in accordance with our Privacy Policy.