missing translation for 'onlineSavingsMsg'
Learn More

Invitrogen™ mRNA Catcher™ PLUS Purification Kit

Codice prodotto. 10594823
Cambia vista
Click to view available options
Quantity:
96 Preps
960 Preps
Product Type:
Buffers Only
Purification Kit
Dimensione della confezione:
Each
3 product options available for selection
Product selection table with 3 available options. Use arrow keys to navigate and Enter or Space to select.
Codice prodotto. Quantity Product Type Dimensione della confezione
10594823 96 Preps Purification Kit Each
10247402 960 Preps Purification Kit Each
10105302 960 Preps Buffers Only Each
Use arrow keys to navigate between rows. Press Enter or Space to select a product option. 3 options available.
3 options
Les retours ne sont pas autorisés pour ce produit. Consulta la politica di reso

For Research Use Only. All usage must comply with product instructions.

Codice prodotto. 10594823 Fornitore Invitrogen™ N. del fornitore K157002
Follow the Workflow - Explore the Savings
Use promo code 27967
Visualizza tutte le promozioni
 Restricted Item
Estimated Shipment: 22-12-2026
Aggiungi al carrello
Aggiungi al carrello

missing translation for 'validMainframeMsg'

Les retours ne sont pas autorisés pour ce produit. Consulta la politica di reso

For Research Use Only. All usage must comply with product instructions.

Includes

1 96-well mRNA Catcher PLUS plate; 4mL 2X Lysis Buffer L20; 30mL Wash Buffer W15; 4mL Dilution Buffer DL1; 8mL Elution Buffer E3; 100μL 0.5M DTT (4°C)

The mRNA Catcher PLUS Purification Kit enables high-throughput purification of mRNA from cells, tissues, blood, and total RNA in a 96-well format.

The mRNA Catcher PLUS Purification Kit enables high-throughput purification of mRNA from cells, tissues, blood, and total RNA in a 96-well format. By taking advantage of locked nucleic acid (LNA) technology, the mRNA Catcher PLUS kit provides improved performance and a faster protocol, while preserving mRNA yield and purity.

The mRNA Catcher PLUS Purification Kit offers:

  • Robust performance—high binding capacity per well (>80 ng/well)
  • Reproducible results—low CVs from well-to-well and plate-to-plate (∼2%)
  • Optimized protocols—for small sample sizes (100 cells, 4 mg tissue, and 40 μL blood)
  • Compatible plate design—may be used with most PCR cyclers

How it works

mRNA from total RNA, cells, tissue, and blood samples is hybridized to an immobilized, single-stranded 20-mer oligo(dT)-containing LNA. The incorporation of LNA into the oligo probe increases the hybridization efficiency and specificity of the mRNA binding. The mRNA can either be eluted or reversed-transcribed to cDNA directly in the well. The mRNA Catcher PLUS method does not require centrifugation, precipitation, phase separation, or column filtration. In addition, the entire method is amenable to automation for streamLined, high-throughput expression profiling for large-scale processes. Isolated mRNA is suitable for use in downstream applications such as RT-PCR and qRT-PCR.

Order Info

Shipping Condition: Wet ice

TRUSTED_SUSTAINABILITY

Specifica

Content And Storage • 1 x 96-well mRNA Catcher™ PLUS Plate; store at 4°C
• 4 mL 2X Lysis Buffer L20; room temperature
• 30 mL Wash Buffer W15; room temperature
• 4 mL Dilution Buffer DL1; room temperature
• 8 mL Elution Buffer E3 (DEPC-treated RNase-free water); room temperature
• 100 μL 0.5M DTT; 4°C
Isolation Technology Oligo dT Affinity
Purification Time 1.5 hr. (Including sample homogenization)
Elution Volume 80 μL
Sample Type Cells, Tissue, Total RNA, Whole Blood
Final Product Type mRNA
High-throughput Compatibility High-throughput Compatible
For Use With (Equipment) Robotic Liquid Handling Systems
For Use With (Application) RT-PCR, qPCR, cDNA Library Construction, Microarray Analysis
Product Type Purification Kit
Quantity 96 Preps
Shipping Condition Room Temperature
Starting Material Amount Cells: 100–106, Tissue: 4–40 mg, Total RNA: 0.1–100 μg, Whole Blood: 40 μL
Yield >80 ng
Vedi altri risultati Mostra meno risultati

For Research Use Only. Not for use in diagnostic procedures.

Titolo del prodotto
Selezionare un problema

Facendo clic su Invia, l'utente riconosce che potrebbe essere contattato da Fisher Scientific in merito al feedback fornito in questo modulo. Non condivideremo le vostre informazioni per altri scopi. Tutte le informazioni di contatto fornite saranno conservate in conformità con la nostra Politica sulla privacy. Informativa sulla privacy.