Macherey-Nagel™ PERMABOND™ CW 20 M Capillary Columns, 0.32mm ID
Designed for use in gas chromatography. Macherey-Nagel™ PERMABOND™ CW 20 M Capillary Columns, 0.32mm ID are composed of 20,000 Da polyethylene glycol. These polar phase columns are recommended for solvent analysis and alcohols, and are suitable for use with aqueous solutions.
Max. Temperature | 220°C (long term), 240°C (in temperature program) |
---|---|
Type | GC Capillary Column |
Stationary Phase | Permabond™ CW 20 M |
Packing Material | Poly(ethylene glycol) |
Diameter (Metric) | 0.5 mm |
Diameter (Metric) Inner | 0.32 mm |
Quantity | 1 Each |
Functionality/Interaction Type | Polar phase |
USP Type | G16 |
Macherey-Nagel™ PERMABOND™ CW 20 M Capillary Columns, 0.25mm ID
Designed for use in gas chromatography. Macherey-Nagel™ PERMABOND™ CW 20 M Capillary Columns, 0.25mm ID are composed of 20,000 Da polyethylene glycol. These polar phase columns are recommended for solvent analysis and alcohols, and are suitable for use with aqueous solutions.
Max. Temperature | 220°C (long term), 240°C (in temperature program) |
---|---|
Type | GC Capillary Column |
Stationary Phase | Permabond™ CW 20 M |
Packing Material | Poly(ethylene glycol) |
Diameter (Metric) | 0.4 mm |
Diameter (Metric) Inner | 0.25 mm |
Quantity | 1 Each |
Film Thickness | 0.25 μm |
Functionality/Interaction Type | Polar phase |
USP Type | G16 |
Trajan™ BP21 (FFAP) GC Capillary Columns
A very polar nitroterephthalic acid modified PEG phase suited to the analysis of free fatty acids
Stationary Phase | Polyethylene Glycol |
---|---|
Packing Material | BP21 (FFAP) |
Polarity | Polar |
Temperature Range | 35°C to 240/250°C |
Coating | Fused Silica |
USP Type | G25, G35 |
Macherey-Nagel™ PERMABOND™ CW 20 M Capillary Columns, 0.53mm ID
Designed for use in gas chromatography. Macherey-Nagel™ PERMABOND™ CW 20 M Capillary Columns, 0.53mm ID are composed of 20,000 Da polyethylene glycol. These polar phase columns are recommended for solvent analysis and alcohols, and are suitable for use with aqueous solutions.
Max. Temperature | 200°C (long term), 220°C (in temperature program) |
---|---|
Type | GC Capillary Column |
Stationary Phase | Permabond™ CW 20 M |
Packing Material | Poly(ethylene glycol) |
Diameter (Metric) | 0.8 mm |
Diameter (Metric) Inner | 0.53 mm |
Quantity | 1 Each |
Functionality/Interaction Type | Polar phase |
USP Type | G16 |
Stationary Phase | SGE™ BP20 (Wax) |
---|---|
Polarity | Polar |
Trajan Scientific and Medical™ Capillary GC column BP21 (FFAP)
A very polar nitroterephthalic acid modified PEG phase suited to the analysis of free fatty acids
Macherey-Nagel™ PERMABOND™ CW 20 M Capillary Columns, 0.1mm ID
Designed for use in gas chromatography. Macherey-Nagel™ PERMABOND™ CW 20 M Capillary Columns, 0.1mm ID are composed of 20,000 Da polyethylene glycol. These polar phase columns are recommended for solvent analysis and alcohols, and are suitable for use with aqueous solutions.
Trajan Scientific and Medical™ Capillary GC Column
Ideal for use with alcohol, free acids, fatty acid methyl esters, aromatics, solvents, and essential oils
Thermo Scientific™ TRACE™ TR-Wax GC Columns
Analyze a wide range of polar compounds with this low-bleed, general purpose, high polarity GC column.
Stationary Phase | Trace™ TR-WAX |
---|---|
Polarity | Polar |
USP Type | G16, G20 |
Thermo Scientific™ TraceGOLD™ TG-WaxMS B GC Columns
Identify basic analytes with high performance, sensitivity, and reproducibility without derivatization or column priming.
Max. Temperature | 200/220°C |
---|---|
Stationary Phase | TraceGOLD™ TG-WAXMS B |
Polarity | Polar |
Thermo Scientific™ TraceGOLD™ TG-WaxMS GC Columns
Analyze FAMEs with excellent thermal stability using this column.
Max. Temperature | 240/260°C |
---|---|
Stationary Phase | TraceGOLD™ TG-WAXMS |
Polarity | Polar |
USP Type | G14, G15, G16, G20, G39 |
Thermo Scientific™ TRACE™ TR-WaxMS GC Columns
Use this low-bleed, highly stable polar GC column for high-polarity separations for MS analysis.
Max. Temperature | 280/300°C |
---|---|
Stationary Phase | Trace™ TG-WAXMS |
Polarity | Polar |
For Use With (Application) | GC/MS for Aromatic Hydrocarbons, Alcohols, Esters, Aldehydes, and Ketones,GC/MS for Food Additives and Essential Oils |
USP Type | G16 |
Thermo Scientific™ TRACE™ TR-FFAP GC Columns
Maintains low-bleed even at elevated temperatures. Choose these columns for outstanding robustness in difficult-to-analyze separations.
Max. Temperature | 240/250°C |
---|---|
Stationary Phase | Trace™ TR-FFAP |
Polarity | Polar |
USP Type | G25, G35 |
Thermo Scientific™ TraceGOLD™ TG-WaxMT Metal GC Columns
Ensure excellent column-to-column reproducibility using the Thermo Scientific™ TraceGOLD™ TG-WaxMT GC Columns.
Max. Temperature | 260°C |
---|---|
Stationary Phase | TraceGOLD™ TG-WAXMS |
Polarity | Polar |
Temperature Range | 40°C°C to 260°C |
For Use With (Application) | GC for EPA Method 603 for Acrolein/Acrylonitrile,GC for Fatty Acid Methyl Esters (FAMEs), Flavor Compounds, Essential Oils, Amines, Solvents, and Xylene Isomers |
USP Type | G14, G15, G16, G20, G39 |
Thermo Scientific™ TraceGOLD™ TG-WaxMS A GC Columns
Identify organic acids with high performance, sensitivity and reproducibility while preventing oxidative damage with this low-bleed, polar GC column.
Max. Temperature | 240/250°C |
---|---|
Stationary Phase | TraceGOLD™ TG-WAXMS A |
Polarity | Polar |
USP Type | G25, G35 |