missing translation for 'onlineSavingsMsg'
Learn More

Invitrogen™ Annexin V Ready Flow Conjugates for Apoptosis Detection

Catalog No. 15719039
Ansicht ändern
Click to view available options
Anregung/Emission:
410/455
495/519
650/660
650/665
Farbe:
Blau
Grün
Rot
Tiefrot
Konjugat:
APC (Allophycocyanin)
Alexa Fluor 488
Alexa Fluor 647
Pacific Blue
Unit Size:
120 Reaktionen
4 product options available for selection
Product selection table with 4 available options. Use arrow keys to navigate and Enter or Space to select.
Product Code. Anregung/Emission Farbe Konjugat Unit Size
15719039 495/519 Grün Alexa Fluor 488 120 Reaktionen
15874943 650/665 Tiefrot Alexa Fluor 647 120 Reaktionen
15884943 650/660 Rot APC (Allophycocyanin) 120 Reaktionen
15894943 410/455 Blau Pacific Blue 120 Reaktionen
Use arrow keys to navigate between rows. Press Enter or Space to select a product option. 4 options available.
4 options
This item is not returnable. View return policy

Nur f\u00FCr Forschungszwecke. Die Anwendung muss den Produktanweisungen entsprechen.

Product Code. 15719039 Supplier Invitrogen™ Supplier No. R37174
Black Friday beginnt hier
Verwenden Sie den Aktionscode 27984
View all promotions
 Eingeschränkter Artikel
In Stock
Add to basket
Add to basket

missing translation for 'validMainframeMsg'

This item is not returnable. View return policy

Nur f\u00FCr Forschungszwecke. Die Anwendung muss den Produktanweisungen entsprechen.

Annexin V Konjugat-Färbemittel ermöglichen die einfache Bestimmung apoptotischer Zellen über die Durchflusszytometrie.

Die gebrauchsfertigen eigenständigen Annexin V Ready Flow Konjugat-Färbemittel bieten mittels Durchflusszytometrie eine bis zu 100-fache Signalintensität bei der Fluoreszenz zwischen apoptotischen und nicht apoptotischen Zellen. Es ist nicht erforderlich, die Konjugat-Färbemittel zu verdünnen, zu wiegen oder zu pipettieren. Fügen Sie einfach einen Tropfen in die Zellen ein, inkubieren und analysieren Sie sie.

Annexin V conjugates provide quick and reliable detection methods for studying the externalization of phosphatidylserine, an indicator of intermediate stages of apoptosis. The difference in fluorescence intensity between apoptotic and nonapoptotic cells stained with our fluorescent annexin V conjugates, as measured by flow cytometry, is typically about 100-fold.

The Annexin V Ready Flow conjugates are provided as ready-to-use, direct-to-sample apoptotic cell stains. Simply add one drop from the dropper bottle directly into 1 x 105 cells in 2.5 mM Ca2+-containing cell culture medium or annexin binding buffer (Cat. Nos. V13246 or BMS500BB), incubate, and analyze. The traditional annexin staining protocol can be used as an alternative method by replacing the addition of 5 μL annexin conjugate with the addition of 1 drop from the Ready Flow dropper bottle, following the volumes and incubation conditions as indicated.

The Annexin V Alexa Fluor 488 conjugate is excitable at 495 nm with an emission peak at 519 nm.

The Annexin V Alexa Fluor 647 conjugate is excitable at 650 nm with an emission peak at 665 nm.

The Annexin V APC conjugate is excitable at 650 nm with an emission peak at 660 nm.

The Annexin V Pacific Blue conjugate is excitable at 410 nm with an emission peak at 455 nm.

Annexin V staining to detect apoptotic cells can only be done on live cells and tissue. If samples are to be fixed post-staining, there are specific conditions required to achieve transient retention of signal. These include use of an alcohol-free, aldehyde-based fixation method, use of buffers containing Ca2+ and avoidance of surfactants/detergents. For your convenience, we also offer a concentrated annexin-binding buffer that facilitates the binding of annexin V to phosphatidylserine in apoptosis assays.

TRUSTED_SUSTAINABILITY

Specifications

Beschreibung Annexin V Alexa Fluor 488 Ready Flow Konjugat
Menge 2 Dropper Bottles
Produkttyp Ready Flow Konjugat
Inhalt und Lagerung Bei 2-8°C lagern.
Durchflusszytometer-Laserlinien Blau
Anregung/Emission 495/519
Anzahl Reaktionen 120
Farbe Grün
Versandbedingung Raumtemperatur
Konjugat Alexa Fluor 488
Zur Verwendung mit (Geräte) Durchflusszytometer
Show More Show Less
Product Title
Select an issue

By clicking Submit, you acknowledge that you may be contacted by Fisher Scientific in regards to the feedback you have provided in this form. We will not share your information for any other purposes. All contact information provided shall also be maintained in accordance with our Privacy Policy.