missing translation for 'onlineSavingsMsg'
Learn More

Labconco™ 1800 mm ReVo Class II, Type A2 Microbiological Safety Cabinet

Product Code. 17890754 Shop All Labconco Corporation Products
Change view
Click to view available options
Ports:
Schuko Plug
Includes:
Base Stand
Base Stand Not Included
Unit Size:
1 unit
2 product options available for selection
Product selection table with 2 available options. Use arrow keys to navigate and Enter or Space to select.
Product Code. Ports Includes unitSize
17890754 Schuko Plug Base Stand Not Included 1 unit
17880744 Schuko Plug Base Stand 1 unit
Use arrow keys to navigate between rows. Press Enter or Space to select a product option. 2 options available.
2 options
This item is not returnable. View return policy
Product Code. 17890754 Supplier Labconco™ Supplier No. 3R2610031

Please to purchase this item. Need a web account? Register with us today!

This item is not returnable. View return policy

ReVo™ Class II, Type A2 Microbiological Safety Cabinets provide personnel, product and environmental protection from biohazardous agents and hazardous particulates.

  • Provide personnel, product and environmental protection from biohazardous agents and hazardous particulates.
  • Other appropriate applications include work with antineoplastic drugs, genetic material, and additional substances that generate hazardous airborne particulates..
  • All models are EN 12469 compliant with additional certification by TÜV Nord.
  • These biological safety cabinets are designed to discharge HEPA-filtered exhaust air directly into the laboratory, or into an exhaust system through the optional Canopy Connection.
  • When canopy-connected, the biosafety cabinets may be used for applications involving minute quantities of volatile toxic chemicals and tracer amounts of radionuclides as an adjunct to microbiological research.
  • During operation, room air is drawn into the inlet grill.
  • The air in the plenum beneath the work surface is a mixture of unfiltered room air and air that has just passed through the work area.
  • This contaminated air is drawn by the blower through the back plenum of the cabinet, where approximately 70% of the air is recirculated through the supply HEPA filter and back over the work area.
  • The balance of the contaminated air is discharged to the environment after passing through the exhaust HEPA filter.

Specifications

Certifications/Compliance EN 12469 Certified by TÜV
Chamber Material Stainless Steel (304)
Product Type Class II Biosafety Cabinet
Noise Level 52 dBA
Outlets 2
Power Consumption 240 W
Sash Opening (Metric) 200 mm
Exhaust Air Filter HEPA Exhaust Filter
Filter Type H14 HEPA
Includes Base Stand Not Included
Ports Schuko Plug
Sash Opening (English) 7.87 in.
Dimensions (L x W x H) Exterior 797 x 1941 x 1350 mm
Shipping Weight (Metric) 262.0 kg
Voltage 230 V
Show More Show Less